Browse all practice questions for the Commercial Food Equipment Service Association (CFESA) Refrigeration Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Commercial Food Equipment Service Association (CFESA) Refrigeration Certification Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the importance of proper insulation in refrigeration systems?
  • When should a suction drier be left in the refrigeration line?
  • If a compressor has a rated FLA of 20A but is drawing 26A while running, what is a possible issue?
  • How does a two-stage refrigeration system operate?
  • An automatic expansion valve does not:
  • What is the purpose of the suction line in a refrigeration system?
  • Which refrigerant is a suitable interim replacement for R-12?
  • What could be a potential risk if the compressor fails in a refrigeration system?
  • What could happen if the condenser fan motor is not cleaned?
  • When is it necessary to evacuate a refrigeration system?
  • Excessive moisture in a reach-in cooler typically suggests what issue?
  • Which phrase best describes the proper use for a refrigerated box using a cap tube system?
  • Which condition can lead to compressor failure due to high temperatures?
  • Which of the following is a key component in assessing the health of a refrigeration system?
  • Where is a pump down solenoid valve typically located?
  • How does ambient temperature impact refrigeration system performance?
  • Which box operates with higher humidity based on the temperature difference?
  • What is the primary function of the compressor in a refrigeration system?
  • Where is the best location to remove acid from a refrigerant system?
  • Where must the sensor bulb on a TEV be mounted?
  • What is a major problem with POE oil?
  • Why is a proper refrigerant charge critical in refrigeration systems?
  • What is a common indicator of a clogged filter in a refrigeration system?
  • If the TD of an evaporator coil should be 15 ° and you measure only 5 °, what could be the issue if other pressures check out?
  • Why is it necessary to remove a grease-covered condenser?
  • An R404A cooler system with a cap tube has a head pressure of 336 psi. What may this indicate?
  • In order to maintain proper temperature under various loads, a cooler or freezer located on a front prep line must be equipped with:
  • What is a significant advantage of a balanced port TEV?
  • What happens to a refrigeration system when moisture is present?
  • A cap tube is ineffective on most commercial refrigeration systems because:
  • What is the procedure for checking the suction valves on a compressor?
  • After completing repairs on a freezer, why might the temperature stop dropping at 35 degrees?
  • Why is measuring compression ratio critical for a compressor's life?
  • What is a key aspect of maintaining balanced port expansion valves?
  • What is subcooling in the context of refrigeration systems?
  • What instrument is used to measure the pressure in a refrigeration system?
  • What does the start relay disconnect when the motor reaches about 2/3 of its full speed?
  • What is typically the first sign of a cap tube issue?
  • What does it indicate if a compressor is short-cycling?
  • What should be checked when a compressor is operating inefficiently?
  • What function does the evaporator serve in a refrigeration system?
  • Why is it important to clean grease buildup on the condenser fan motor and blade?
  • When replacing driers for newer refrigerants, what size should they be?
  • What factor can lead to compressor overheating in a refrigeration system?
  • Which of the following is NOT a main component of a refrigeration system?
  • What environmental factor significantly impacts the efficiency of condensing units in refrigeration systems?
  • What can cause frost build-up around the evaporator coil?
  • What role do defrost timers play in commercial refrigeration systems?
  • What does a dark brown or black color with carbon deposits on a compressor's valve plate indicate?
  • According to HACCP food safety regulations, what temperature must coolers maintain?
  • Is it advisable to install a sight glass in a cap tube system?
  • What is an effect of not addressing low refrigerant levels?
  • How many BTUs per hour is one ton of refrigeration equal to?
  • What is the maximum allowable discharge temperature to prevent probable compressor failure?
  • What happens when the defrost termination thermostat reaches its temperature limit?
  • What does the coefficient of performance (COP) indicate?
  • What leads to effective acid removal from the refrigerant?
  • For maximum efficiency, the thermal expansion valve superheat for a freezer should be about:
  • In subcooling calculations, why is the position of the temperature sensor important?
  • If the oil sight glass in a compressor shows almost no oil and there are no leaks, what should be the next step?
  • What is the purpose of an evaporator fan in commercial refrigeration?
  • What is a common reason for a refrigeration system to fail to activate cooling?
  • What is the primary function of a fan delay thermostat in commercial freezers?
  • What are signs indicating a malfunctioning expansion valve?
  • What are common refrigerant types used in commercial kitchens?
  • What occurs to the water flow rate when the condensing unit is off?
  • What line is typically used to provide heat for evaporating condensate in many commercial reach-in boxes?
  • What is the purpose of a condenser in the refrigeration cycle?
  • What is a possible cause for the suction valves snapping off when the compressor head is removed?
  • Where is a run capacitor connected in a motor system?
  • What does the milky color of oil in a compressor most likely indicate?
  • Why is superheat crucial in a refrigeration system?
  • Which condition likely indicates a problem when turning off a refrigeration unit?
  • How should a fan blade be positioned in an evaporator or condenser?
  • What must be matched when replacing an evaporator fan motor?
  • Where should a sight glass/moisture indicator be installed in a refrigeration system?
  • The new interim refrigerants R401A, R401B, and R409A have what characteristic related to heat carrying capacity?
  • When evacuating a refrigeration system, which tool is essential to ensure a proper evacuation?
  • What is the main role of an accumulator in a refrigeration system?
  • What is the most common cause of leaks in the middle of a copper line?
  • A dark colored moisture indicator sensor suggests what condition in a refrigeration system?
  • When bubbles are present in a sight glass, what does this indicate when using near azeotropic refrigerants?
  • What is the best example of the definition of a storage box?
  • What characteristic of mineral oil makes it suitable for use with CFC refrigerants?
  • For maximum system efficiency, the TEV superheat for a cooler should be about:
  • If a start capacitor rated at 240 uf and 225 volts is faulty, which capacitor can be used instead?
  • If the shroud is missing from the condenser on a condensing unit, what should be done?
  • What causes excess superheat increase on the way to the compressor?
  • What effect does insufficient refrigerant charge have on a refrigeration system?
  • Why must a condenser fan blade be replaced with the exact factory-supplied blade?
  • When sizing the piping for a refrigeration system, which line is most critical?
  • When checking for correct superheat on a cap tube system, what condition is required?
  • Which refrigerant serves as a drop-in replacement for R502?
  • What action should be taken if the condenser is badly clogged?
  • What usually causes partial or complete clogging in capillary tubes?
  • If an R404A system has a suction pressure of 29 psi and a head pressure of 239 psi, what is the superheat?
  • Which type of cleaner is most effective for cleaning greasy condenser coils?
  • What is the appropriate method to perform a leak check in a refrigeration system?
  • What is indicated by the terminal marked as 'A' in a common terminal identification?
  • What is the primary risk of using a run capacitor that is not functioning properly?
  • Why can pressure controls not be used as the sole source of temperature control in outdoor temperature climates?
  • A missing condenser fan shroud on a cap tube system will probably lead to what?
  • What issue is indicated by the oil sight glass showing almost no oil in a compressor?
  • Why is it crucial to adhere to EPA regulations in refrigeration service?
  • What should be done to a grease-laden air-cooled condenser?
  • When should a condenser capacity be assessed?
  • Which refrigerant would you convert a walk-in freezer to when replacing the condensing unit on an R502 system?
  • What is one way to maintain proper airflow in a refrigeration system?
  • What does proper refrigerant handling ensure?
  • Why is monitoring ambient temperature crucial in refrigeration systems?
  • What is the purpose of a low-pressure switch in refrigeration systems?
  • What is the primary function of the high-pressure switch in a refrigeration system?
  • What is the typical duration set for defrost timers in commercial freezers?
  • What is a sign of a compressor burnout?
  • Which cleaning agents are advisable for servicing refrigeration coils?
  • What impact do high superheat settings have on a refrigeration system?
  • What should be done if there are bubbles in the sight glass of a refrigeration system?
  • What is an interim refrigerant choice for an R502 system with a major leak?
  • What is a potential consequence of improper refrigerant levels in a refrigeration system?
  • What is the primary purpose of a thermal expansion valve in a refrigeration system?
  • If a cap tube is partially clogged, what is an expected condition?
  • What is a crucial reason for insulating the suction line?
  • What is the primary purpose of a refrigeration system in commercial food service?
  • How does regular maintenance benefit refrigeration systems?
  • In a low-temperature refrigeration system, the majority of Btu of cooling is required to remove what?
  • What pressure corresponds to 20°F on R404A?
  • What causes a refrigeration system to run continuously?
  • When is it necessary to replace a compressor?
  • What is the primary reason a condensing unit located in a restricted space will run higher than normal head pressures?
  • What is the role of the condenser in the refrigeration cycle?
  • How can you identify a compressor that suffered from liquid slugging?
  • How can you confirm that a refrigeration system is properly charged?
  • If the liquid line out of the liquid line drier is frosted, what does this suggest?
  • What environmental factor can contribute to compressor failures?
  • Where is the most effective place to remove moisture from refrigerant?
  • What is the status of contacts on a potential relay when not energized?
  • Where must a static condenser be installed?
  • In what way does the refrigeration cycle specifically differ from the air conditioning cycle?
  • Where should a temperature sensor be installed to accurately calculate subcooling?
  • What is the main function of a drier in a refrigeration system?
  • Why is a bleed resistor necessary on a start capacitor?
  • What can help mitigate the issue of bubbles showing in sight glasses with a full charge?
  • What happens to the compressor when the condensing temperature at the compressor head reaches 350 °?
  • What is the primary benefit of balanced port expansion valves?
  • What is the recommended oil level in the sight glass of a running semi-hermetic compressor?
  • What is the consequence of dirty and clogged evaporator coils?
  • Where should the discharge temperature be measured in a refrigeration system?
  • What is the role of an electrical schematic in refrigeration troubleshooting?
  • What is the most important line to ensure proper oil return during piping installation?
  • What is a major consequence of undercharging a refrigeration system?
  • In refrigeration systems, what role does a sight glass play when properly installed?
  • What is a common reason for the premature failure of replacement compressors?
  • What type of maintenance is necessary for condensers in refrigeration systems?
  • What is the maximum allowable voltage difference for a balanced three-phase compressor?
  • In low temperature climates, what is the most efficient method for temperature control?
  • During a system operation using R134A, what does the system indicate if the suction pressure falls to 15 psi and then into a vacuum?
  • Which statement is true regarding R134A?
  • When should a cap tube be considered for use in a refrigeration system?
  • What is the maximum temperature a freezer must maintain to ensure proper operation?
  • Why is refrigerant classification important for refrigeration systems?
  • Why might bubbles appear in sight glasses when using newer near azeotropic refrigerants?
  • What is the main purpose of the expansion valve in refrigeration?
  • In a system with R134A operating at 146 psi head pressure and 100°F condenser temperature, what is the subcooling measured?
  • What determines the size of the metering device needed for a refrigeration system?
  • What happens if the condenser fan fails in a refrigeration system?
  • What is the main purpose of using a properly designed drier in a refrigeration system?
  • What is the maximum head pressure for an R404A system operating in an ambient temperature of 85°F?
  • What symptom might indicate a faulty thermostat in a refrigeration unit?
  • How should R404A be charged into a refrigeration system?
  • Where should the sensor bulb on an external equalized TXV be mounted?
  • What is the purpose of a water regulating valve in a water-cooled condenser?
  • What is the total capacitance of two 100 uf capacitors connected in parallel?
  • What type of oil is recommended for use with refrigerant R404A?
  • Why do modern three-phase compressors often require crankcase pressure regulating (CPR) systems?
  • What is a common issue with coolers and freezers that use a coiled discharge line in a pan for condensate removal?
  • What is a typical symptom of a malfunctioning compressor?
  • What is the primary function of an accumulator in a refrigeration system?
  • What is the main consequence of improper refrigerant charge?
  • Which component removes heat from the refrigerant, allowing it to cool and condense?
  • Which component helps prevent corrosion in a refrigeration system?
  • What effect does a missing condenser fan shroud have on discharge pressure?
  • What is the best course of action when there are concerns with refrigerant levels in a compressor with low oil?
  • What is true about compression ratio in relation to volumetric efficiency?
  • What is a key disadvantage of using an automatic expansion valve?
  • What is a characteristic of a near azeotrop refrigerant?
  • What is a common method to identify leaks in a refrigeration system?
  • What safety precautions should be observed while working with refrigeration systems?
  • What does a dry system indicated by a moisture indicator imply for the refrigeration system's functionality?
  • What maintenance action is necessary for a refrigeration compressor after a defrost cycle?
  • What condition can cause discharge valves and backing plates on a compressor valve plate to be deformed?
  • What is the function of a defrost termination thermostat on a walk-in freezer?
  • What type of oil is most commonly used with CFC refrigerants?
  • How do you reduce the superheat on a thermal expansion valve?
  • What is the benefit of using leak detectors in refrigeration maintenance?
  • What does icing around a freezer door frame typically indicate?
  • Which tool is essential for troubleshooting refrigeration issues?
  • What should you do if an ohmmeter reads infinity ohms when checking a start capacitor?
  • What is a common characteristic of a high-quality vacuum pump used in system evacuation?
  • What does the term 'latent heat' refer to in refrigeration contexts?
  • What could indicate that a refrigeration system is overcharged?
  • What preventative measures can help avoid compressor failure?
  • Which maintenance task is critical for evaporators?
  • Which of the following best describes the process of condensation in a refrigeration system?
  • Which part of the refrigeration system is crucial for removing moisture?
  • How does a compressor function within a refrigeration system?
  • Where must the sensor bulb on a TEV be installed on the suction line?
  • How are cooler evaporators typically defrosted?
  • Which process occurs in the evaporator coil?
  • What is a common cause for evaporator failures in reach-in coolers?
  • What does the compression ratio represent in refrigeration systems?
  • Which factor is essential for maintaining optimal performance in a refrigeration system?
  • Why are forced air evaporator coils commonly used in refrigeration systems?
  • What is an essential part of routine maintenance for refrigeration systems?
  • What equipment should be installed to handle the system for newer refrigerants?
  • Where should a trap be installed when piping refrigerant lines in a system with the compressor above the evaporator?
  • What is important to consider when re-soldering refrigerant lines?
  • How should one check the discharge valves on a compressor?
  • A system that runs at a superheat of 1 ° F will likely result in what?
  • What is a thermal expansion valve (TXV) used for in refrigeration systems?
  • What type of contacts are found on a current relay?
  • Which factor is crucial when selecting a pump for evacuating refrigeration systems?
  • How is a coil on a current relay typically connected?
  • What does the capacity of a one horsepower compressor depend on?
  • What commonly contributes to high head pressure in a refrigeration unit?
  • When replacing valve plates or service valves, what should be used to lubricate the gaskets?
  • What should be monitored to prevent damage to relay contacts in a compressor's circuitry?
  • What is the role of the evaporator in a refrigeration system?
  • How does a balanced port expansion valve differ from other types?
  • What action is needed to ensure the suction pressure remains the same during testing?
  • What effect does temperature have on the performance of refrigeration systems during evacuation?
  • If the suction line to a compressor using a TEV is frosted and iced up, it could indicate what issue?
  • When converting a system from R502 to R404A, what can you do with the TEV?
  • When evacuating a refrigeration system, to what micron level should it ideally be evacuated?
  • When replacing a refrigerant cap tube with a generic cap tube kit, what is the first step to follow?
  • Which of the following is a sign of a refrigerant leak?
  • What is superheat in the context of refrigeration?
  • What happens at the expansion valve in a refrigeration system?
  • Which refrigerants are commonly used in commercial refrigeration systems?
  • What is a potential consequence of neglecting regular maintenance on refrigeration equipment?
  • Why is regular maintenance important for refrigeration systems?
  • In a potential relay, how is the coil typically wired?
  • What is the primary purpose of a run capacitor in a compressor system?
  • What should be done if an evaporator has an external equalized TEV, but only an internal equalized valve is available?
  • Which component is responsible for maintaining the refrigerant flow in the system?
  • When a compressor kicks the circuit breaker while starting, what could be the likely problem if the FLA rating is 7 amps?
  • After servicing a cap tube system and replacing the drier with a larger one, what is the best way to recharge it?
  • What could lead to a malfunctioning thermal expansion valve?
  • A water-cooled condenser that is operating properly will have what characteristic regarding discharge water temperature?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy